Index index by Group index by Distribution index by Vendor index by creation date index by Name Mirrors Help Search

libsane1-1.3.1-2.2 RPM for armv6hl

From OpenSuSE Ports Tumbleweed for armv6hl

Name: libsane1 Distribution: openSUSE Tumbleweed
Version: 1.3.1 Vendor: openSUSE
Release: 2.2 Build date: Tue Aug 6 15:46:39 2024
Group: Hardware/Scanner Build host: reproducible
Size: 166856 Source RPM: sane-backends-1.3.1-2.2.src.rpm
Packager: http://bugs.opensuse.org
Url: http://www.sane-project.org/
Summary: Core SANE library
This contains the SANE library. Individual scanner backends are provided
by sane-backends or third party packages.

Provides

Requires

License

GPL-2.0-or-later AND LGPL-2.1-or-later AND SUSE-Public-Domain

Changelog

* Tue Aug 06 2024 John Paul Adrian Glaubitz <adrian.glaubitz@suse.com>
  - Cherry-pick upstream patch to remove unnecessary Unicode character
    * remove_unnecessary_unicode_character.patch
  - Use individual %patch statements over %autosetup to allow
    for different levels of path stripping for both patches
* Thu May 23 2024 Arnav Singh <opensuse@arnavion.dev>
  - Updated to sane-backends version 1.3.1
    * Re-release of 1.3.0 because upstream unreleased 1.3.0 due to VCS issues.
      ( https://gitlab.com/sane-project/backends/-/issues/751 )
* Fri May 03 2024 Arnav Singh <opensuse@arnavion.dev>
  - Updated to sane-backends version 1.3.0
    * Backends
      + avision:
    - Correction for ADF presence detect which caused a hang.
    - Internationalised some text items in the backend to make them available for translation.
      + epsonds:
    - Some small changes to option documentation.
    - Added support for models: ES-C220, DS-C330, and DS-C490.
      + escl:
    - Fix for pwf:Version item.
    - Fix for crash in libjpeg when cropping image.
    - Fix for issue with configured device when AVAHI not running.
    - Fix for build without poppler-glib.
      + fujitsu:
    - Added support for Ricoh scanners: FI-8040, FI-70F.
      + genesys:
    - Added missing configuration for Plustek OpticFilm 7500i and Plustek OpticFilm 8100.
      + hpljm1005:
    - Fixes to maximum geometries and various cropping and geometry details specifically for
      the HP LaserJet M1005.
      + lexmark_X2670:
    - Added new backend for the Lexmark X26xx series of scanners.
      + pixma:
    - Fix to prevent mode change when source is selected. Mode should not change if still valid
      for source.
    - Added support for models: TS8630 Series, XK110 Series, GX3000 Series, GX4000 Series,
      G3070 Series, G2070 Series, G4070 Series, G3030 Series, G2030 Series, TC-20M, TC-5200M,
      TR4500 Series, TS8700 series, XK120 series, GX1000 series, GX2000 series, TS6630 series,
      TS7700 series, TS7600i series, TS6730 series, TR7800 series, TS7700i series,
      TS7700A series, GX6500 series, i-SENSYS MF750 Series
      + snapscan:
    - Corrections for Agfa ARCUS 1200 scan area.
      + test:
    - Fix for a crash in the backend.
      + xerox_mfp:
    - Added support for Dell 1135n, which is a clone of the Samsung SCX-4623F.
    - Added support for Xerox WorkCentre 3335.
    - Added JPEG mitigation for modules that don't properly support JPEG output:
      Xerox WorkCentre 3225
    - Fix to remove USB CLEAR HALT during initialisation which can potentially lock up devices.
    - General fixes to support the SCX-4521F model.
    * Frontends
      + saned:
    - Default scan buffer is now 1MB. -B option added to permit the buffersize to be set.
    - Documentation fixes.
      + scanimage:
    - Fix for keyboard prompt processing
    - Default scan buffer is now 1MB. --buffer-size and -B options now require an argument
      to be provided.
    - Fix for PDF generation, missing newline in generated file.
    * Build
      + Fixes for clang-16 compiler
      + Fixes for FreeBSD build.
      + Fixes for escl build option involving poppler-glib.
      + Optionally take build version from ChangeLog if not other version source is available.
      + Fixes to autoconf files to remove unnecessary warnings from test logs.
      + Fix for macOS builds related to threading support: SANE in macOS doesn't work for
      multi-process with libusb.
    * Tools
      + sane-find-scanner: Added some Linux SCSI device names since some later potential names
      are missing. Better solution in the pipeline.
    * Documentation
      + Fixes for a number of man pages.
      + Added documentation for a number of Ricoh scanners which are rebranded products acquired
      from Fujitsu.
    * Miscellaneous
      + sanei_config: Fix for a potential crash.
      + New Georgian translation added.
      + Translations updated for: British English, Ukrainian, French and Simplified Chinese.
* Thu Feb 22 2024 Michael Vetter <mvetter@suse.com>
  - Use %autosetup macro. Allows to eliminate the usage of deprecated
    %patchN.
  - Add BuildArch noarch to autoconfig subpackage
* Fri Apr 07 2023 Javier Llorente <javier@opensuse.org>
  - Updated to sane-backends version 1.2.1
    * Backends
      + avision:
    - Minor fix for protocol packet length.
    - Added “basic” support for Avision AD345F. Note that multi-sheet scanning is problematic.
    - Fix for 32-bit limitation on scan line size which caused early abort of scan.
    - Fix for minimum resolution for devices with AV_ASIC_C6.
    - Various small logic errors addressed.
      + canon: Use the common model name instead of string from the device.
      + canon_lide70: Some small corrections to option support.
      + canon_pp: Potential buffer overrun issue addressed.
      + canon-dr: Added support for lifecycle counters for dr-x10c scanners.
      + epjitsu: Hang fix for Scansnap S1300i.
      + epsonds: Added support for Epson XP-2200 Series devices.
      + escl:
    - Fixes related to support for HP M277dw.
    - Fix for Canon TS-3400 series resolution support.
    - Added support for Epson EcoTank L3160.
    - Fix for segfault crash.
    - Performance and memory use enhancements through the use of memory-mapped I/O.
    - Fix for TIFF file type generation failure.
    - IPv6 detection improvements.
      + fujitsu:
    - Contrast/brightness fixes for Fujitsu ix500.
    - Support confirmed for Fujitsu fi-7300NX.
    - Support added for ScanSnap ix1400.
    - Added support for ScanPartner SP30.
      + genesys:
    - Fixes for unit test build errors related to GCC 12.
    - Fix for 32-bit limitation on scan line size which caused early abort. of scan.
    - Build issue fix for OSX.
    - Button support for Canon 8400f scanner corrected.
    - Support added back in for Plustek OpticFilm 7600i: config file entry was missing.
      + kvs40xx: Compiler warnings fixed.
      + mustek_usb2: Compiler warnings fixed.
      + pixma:
    - Fix for Canon TS-3400 series resolution support.
    - Button support for Canon MG5700 series corrected.
    - Added support for Canon imageRUNNER 1018/1022/1023.
    - Added support for Canon PIXMA TS2400 Series.
    - Added support for Canon PIXMA TS2600 Series.
    - Testing confirmed for Canon TS6400 series devices.
    - Testing confirmed for Canon TS3400 series devices.
    - Various devices’ max resolutions fixed.
    - Minor fix for broadcast buffer size error.
      + plustek_pp: Support removed for deprecated Linux kernel driver build.
      + test: Fix for 32-bit limitation on scan line size which caused early abort of scan.
      + xerox_mfp:
    - JPEG support fix for Samsung SCX-4828 FN and similar.
    - JPEG support fix for Samsung SCX-4824 FN and similar.
    * Frontends
      + sane-find-scanner: Alteration to output to indicate that indicated devices are potentially
      scanners.
      + saned: Fix for poll.h header file, which caused problems on Alpine Linux.
      + scanimage:
    - Attempts to set readonly options will give a warning about readonly option set attempt now,
      instead of the misleading "unknown option" error.
    - Header file build fixes for FreeBSD.
    - Fix for backends presenting NULL attributes in deactivated options.
    * Miscellaneous
      + Updated translation to Russian, Italian, British English and Ukraine.
      + Compiler warnings addressed for a number of backends.
      + A number of fixes for the build system:
    - Fix to ignore LDFLAGS environment variable in build.
    - Fix to not build umax_pp tool when disabled.
    - Fix for CLANG compiler warnings.
    - Various small improvements to dependency checking and CI builds.
    - General corrections for backends’ use of mkstemp() function.
    - Added support for autotools’ silent build option.
    - Remove –with-group configure option, since it is no longer used.
    - Autotools fixes for backend library installation.
* Fri Jan 28 2022 Stefan Brüns <stefan.bruens@rwth-aachen.de>
  - Upgraded to sane-backends version 1.1.1
    * Backends
      + epson2: Fixed support for many scanners that don't support
      focus command.
      + epson2: Improve reliability of long scans.
      + epsonds: Implemented support for the following Epson scanners:
    - DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
      DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
      DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
    - ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
      ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
      ES-60WW, ES-65WR,
    - ET-2700 Series, ET-2710 Series, ET-2810 Series,
      ET-M2140 Series, ET-M3140 Series,
    - EW-052A Series,
    - FF-680W,
    - L3150 Series, L3200 Series, L3210 Series, L3250 Series,
      L4150 Series,
    - M2140 Series, M3140 Series,
    - RR-60, RR-600W, RR-70W,
    - XP-2100 Series, XP-2150 Series
      + epson2: Marked XP-452 455 series as supported in
      documentation
      + escl: Fixed scanning problems on certain scanners due to
      incorrect URL being used (#479)
      + escl: Fixed support for different resolutions when using
      JPEG format
      + escl: Fixed handling of ipp-usb redirects to localhost
      which previously caused certain scanners to be always
      reported as busy
      + escl: Added support for Brother DCP-J772DW and Epson
      ET-2750 scanners
      + escl: Marked the following scanners as supported in
      documentation:
    - Canon PIXMA G4511
    - Canon PIXMA TR4550 Series
    - Canon PIXMA TR4551 Series
    - Epson ET-6100
      + escl: Implemented support for disabling PDF output on
      scanners where it's broken (#510)
      + escl: Implemented support for Canon PIXME TR4520 and
      TR7500 scanners
      + genesys: Improved scan quality on Canon LiDE 35/40/50/60
      by using brighter LED illumination
      + genesys: Fixed control of contrast and brigthness on certain
      scanners (#271)
      + genesys: Fixed crashes when handling slightly unexpected
      conditions (#464)
      + genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
      + genesys: Fixed button support on HP ScanJet G4010
      + genesys: Fixed compilation on gcc-4.8
      + genesys: Fixed incorrect LED exposure calculation leading to
      wrong color balance on certain resolutions on gl841 scanners
      + genesys: Improved gray scan quality on Canon LiDE 110, 120,
      210, 220 (#106, #52)
      + genesys: Fixed issue of motor becoming stuck at certain
      resolutions on Canon LiDE 50 and possibly other gl841
      scanners (#357)
      + genesys: Fixed periodic black lines in gray scans on Canon
      LiDE 80
      + genesys: Removed support for broken 75 and 100 dpi hardware
      resolutions to fix preview scans (#383). These resolutions
      did not have any benefit compared to next smallest 150 dpi
      resolution
      + genesys: Add support for running in embedded environments
      that don't support threads
      + genesys: Fixed gray scans to use white color for illumination
      instead of red on Canon LiDE 35/40/50/60 and potentially
      other gl841 scanners. Old behavior can be restored via the
      color filter setting to select specific color component for
      the gray scan
      + genesys: The genesys backend is now distributed under GPL v2
      or later license. Previously there existed an exception that
      allowed additional uses of the backend
      + gt68xx: Fixed several memory issues that can potentially lead
      to crashes or increased memory use
      + hp4200: Fixed crash when using HP ScanJet 4200C (#454)
      + microtek: Fixed support for embedded platforms using uclibc
      + pieusb: Implemented support for Reflecta RPS 10M scanner
      + pieusb: Fixed support for automatically advancing slides on
      DigitDia 4000
      + pixma: Fixed compliation with NDEBUG macro defined
      + pixma: Marked Canon PIXMA G4511 as supported in documentation
      + scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
      as supported
    * Frontends
      + Improved documentation of scanimage concerning options
      provided by backends
      + scanimage: Improved help to specify which options are
      advanced
      + scanimage: Implemented support for PDF output format
  - Cleanup create_hpaio.desc_from_models.dat:
    * Remove scanners unsupported by hplip (scan-type < 0)
    * Simplify and significantly speed it up
* Mon Feb 15 2021 Stefan Brüns <stefan.bruens@rwth-aachen.de>
  - Remove udev rules mangling for USB devices (ATTR vs ATTRS) (!510)
  - Do no add SCSI id twice for EPSON Perfection 1640SU (!509)
* Mon Feb 15 2021 jsmeix@suse.de
  - Upgraded to sane-backends version 1.0.32
    Changes since 1.0.31
    see https://gitlab.com/sane-project/backends/-/blob/master/NEWS
    Numbers of the form '(#NNN)' usually mean upstream issues like
    https://gitlab.com/sane-project/backends/-/issues/NNN and numbers
    of the form '(!MMM)' usually mean upstream merge requests like
    https://gitlab.com/sane-project/backends/-/merge_requests/MMM
    Backends
    * all backends now respect the 'local_only' parameter when 'true'
      is passed to 'sane_get_devices()' in that they do not actively
      go out looking for networked devices (!502)
    * 'artec_eplus48u': fixes configuration for AstraSlim SE (!545)
    * 'avision': adds the AV186+ and AV188 as supported (!532)
    * 'avision': fixes doubled height issue (#402)
    * 'avision': fixes a debug message and compiler warning (!515)
    * 'canon_dr': adds support for the DR-C120 and DR-C130 (#175)
    * 'canon_dr': adds support for uploading of fine calibration
      uploads
    * 'canon_dr': enables fine calibration for the P-208
    * 'canon_dr': improves DR-C225 support (#431)
    * 'canon_lide70': adds support for document scanning
      on the Canon LiDE 600(F), thanks to a hardware donation
      by Georg Sauthoff
    * 'dll': fixes a memory leak (!537)
    * 'epson2': adds support for the ET-2600 (#395)
    * 'epson2': adds autofocus support for devices
      that support it (!531)
    * 'epson2': fixes brightness support for DS-G20000/12000XL (!529)
    * 'epson2': fixes an unchecked return value issue (!526)
    * 'escl': adds support for brightness, threshold, sharpen
      and contrast options (!527, !528)
    * 'escl': adds support for LaserJet FLowMFP M578
      and MFP M630 (#424)
    * 'escl': adds support for DeskJet 2710, 2723 (!519)
      and 3760 (!554)
    * 'escl': adds support for the PIXMA TS-5351 (!544)
      and MG5765 (!517)
    * 'escl': adds support for the Brother HL-L258DW (!517)
    * 'escl': fixes Avahi device discovery (!536)
    * 'escl': fixes crashes for devices without a flatbed (!554)
    * 'escl': fixes segfaults in option handling (!557)
    * 'escl': fixes sleep mode (!577)
    * 'escl': fixes builds without libpoppler-glib-dev (#422)
    * 'escl': fixes a memory issue in its capability handling (#425)
    * 'fujitsu': fixes brightness/contrast for the iX500
    * 'fujitsu': fixes memory corruption for duplex scans
    * 'genesys': disables support for CanoScan 4400F to prevent
      possible physical damage (#436)
    * 'gt68xx': fixes scan cancellation logic (#356)
    * 'pixma': adds untested support for models
      released in 2020 (!553)
    * 'pixma': adds support for ADF scans on the i-SENSYS MF260
    * 'pixma': adds support for PIXMA M340 buttons
      and ADF status (!513)
    * 'pixma': adds an option to control when to calibrate (#321)
    * 'pixma': fixes support for the MX492 (!548)
    * 'pixma': fixes ADF support for the MX490 Series
    * 'pixma': fixes max resolution for ADF scans
      on the PIXMA M320 (#364)
    * 'pixma': fixes compile errors when libxml2
      is not available (#345)
    * 'plustek': fixes CanoScanN650u discovery (#137)
    * 'test': fixes several memory leaks (!537)
    Frontends
    * 'saned': add support for listening on a custom
      or ephemeral port via a new '-p'/'--port' option (!549)
    * 'scanimage': fixes crashes for multi-pass
      and handheld scans (#408)
    * 'scanimage': fixes a memory leak (!551)
    * 'scanimage': fixes option handling
      for non-compliant backends (#362)
    Documentation
    * updates our copy of the GPL with the FSF's current postal
      address. This changes references to the Library GPL (LGPL-2.0)
      into refs to the Lesser GPL (LGPL-2.1) but does *not* affect
      the licensing of our backends (#320).
    * source code now points to the Free Software Foundation's
      website for copies of the GPL and LGPL (#320)
    * updates translations for British English and Ukrainian
    * adds a pointer to our Ubuntu PPA for pre-built binaries
    * adds SCSI IDs for the EPSON Perfection 1640SU (!509)
    * fixes a boat-load of spelling mistakes (!516, thanks @marschap)
    * updates description files for 'scangearmp2'
      and 'utsushi' external  backends
    Build
    * removes support for 'automake' maintainer mode (!522)
    * removes 'sane' subdirectory from the lock directory
      to fix issues when the lock directory is on 'tmpfs' (#363)
    * adds support for builds using GitLab "source" tarballs (#248)
    * fixes static link scenarios (#124)
    * fixes 'python' invocations to use the detected program (!525)
    * disables 'genesys' testsuite when that backend
      is not built (#354)
    * suppresses warnings about obsolete autoconf macros (#122)
    * fixes availability of sane-backends.pot file inputs (#344)
    * fixes 'configure.ac' for use with 'autoconf-2.70' (#409)
    * removes CVS keywords from the source to ease use
      by downstreams that still use CVS (!547)
    Miscellaneous
    * udev rules now trigger on all events other
      than 'remove' (!541). This aims to address a kernel API change
      introduced in 4.14. The new behaviour may slow down udev's
      processing of kernel events when still using our plain 'udev'
      or 'udev+acl' rules, even though these have been optimized
      slightly (#341).  If that bothers you, now is a good time
      to switch to our 'udev+hwdb' rules in combination with
      the 'hwdb' database if you have not done so already.
* Wed Sep 23 2020 jsmeix@suse.de
  - Upgraded to sane-backends version 1.0.31
    Changes since 1.0.30
    see https://gitlab.com/sane-project/backends/-/blob/master/NEWS
    Backends
    * adds the canon_lide70 backend
    * avision: adds support for the KODAK i1120,
      fixes thread cancellation issues,
      disables exposure option for non-filmscanners
    * canon_dr: improves error reporting
    * dmc: fixes compiler warnings on the scan area options
    * epsonds: rewrites the network I/O following changes
      made to the epson2 backend in 1.0.30 to fix security issues.
      Network support is still unsupported.
    * escl: adds ADF support, fixes many minor issues and improves
      error handling. Now also supports devices behind a proxy
      (needs explicit configuration).
    * fujitsu: adds support for the fi-800R and a card scanning
      slot, fixes a bug when reading hardware sensors on the first
      invocation. Adds USB IDs for fi-7800 and fi-7900.
    * genesys: adds support for the Canon 5600F, Canon LiDE 90,
      Plustek OpticFilm 7200 and 7200 (v2), 7400, 7600i, 8100
      and 8200i. Fixes several issues with the Canon 8600F.
      Adds 4800dpi support for the Canon LiDE 210 and fixes 3200dpi
      flatbed support on the Canon 8400F. Adds an option to fill
      dark calibration with a constant. Adds transparency support
      for gl847 chipset based devices. Fixes CIS scanner support
      for gl842 chipset based devices. Removes lineart and image
      enhancement emulation support.
    * gphoto: supports the PLANon DocuPen RC800 (with a recent
      enough version of gphoto2)
    * gt68xx: modifies scan cancellation behaviour
    * hp5400: adds button support, fixes a scan cancellation
      crash issue
    * pixma: add supports for the i-SENSYS MF440 Series and untested
      support for the PIXMMA G7000 Series and GM4000 Series as well
      as the i-SENSYS MF720 Series.
    * plustek: fixes a potential buffer overrun
    * test: adds gamma options
    Documentation
    * removes the SANE Standard. This is now maintained
      as a separate project at
      https://gitlab.com/sane-project/standard
      HTML and PDF versions can be found at
      https://sane-project.gitlab.io/standard/
    * adds and updates information for multiple supported and
      unsupported devices
    * translation updates for British English, French, German,
      Italian and Ukranian
    * scanimage: documents the JPEG compression level
    * minor improvements documenting build requirements
    Build
    * removes the --with-api-spec option from configure
    * replaces the --enable-avahi option with an --with-avahi
      that defaults to enabling if possible. If the option is given
      and the required support is not available, configure will
      exit with an error.
    * improves checking for libjpeg version dependent requirements
    * has been made reproducable (upstream issue 228)
    * fixes build issues on MinGW
    Miscellaneous
    * various fixes and improvements in the USB record/replay support
    * fixes a file descriptor validation test in sanei_pio
    * adds missing include in sanei_usb
  - sane-backends.builttime.patch is no longer needed because the
    issue https://gitlab.com/sane-project/backends/-/issues/228
    is fixed in the upstream sources
* Tue Aug 18 2020 Stefan Brüns <stefan.bruens@rwth-aachen.de>
  - Update to 1.0.30:
    * epson2: fixes CVE-2020-12867 (GHSL-2020-075) and several memory
      management issues found while addressing that CVE
    * epsonds: addresses out-of-bound memory access issues to fix
      CVE-2020-12862 (GHSL-2020-082) and CVE-2020-12863 (GHSL-2020-083),
      addresses a buffer overflow fixing CVE-2020-12865 (GHSL-2020-084)
      and disables network autodiscovery to mitigate CVE-2020-12866
      (GHSL-2020-079), CVE-2020-12861 (GHSL-2020-080) and CVE-2020-12864
      (GHSL-2020-081).  Note that this backend does not support network
      scanners to begin with.
    * magicolor: fixes a floating point exception and uninitialized data
      read
    * fixes an overflow in sanei_tcp_read()
  - Move saned to a separate package
  - Cleanup spec file, remove some obsolete mangling of udev rules

Files

/etc/sane.d
/etc/sane.d/dll.d
/usr/lib/libsane.so.1
/usr/lib/libsane.so.1.2.1
/usr/lib/sane
/usr/lib/sane/libsane-dll.so.1
/usr/lib/sane/libsane-dll.so.1.2.1


Generated by rpm2html 1.8.1